Self supported

  • Wood construction or similar designed buildings are not intended to carry the loads of an elevator system.
  • Buildings with total floor travel up to 85’-0”
  • Elevators capacity up to 3500 lbs.
  • Elevator speeds of 150 fpm.
  • Standard cab finishes and flooring.

Available capacities (by weight)

Speed 150
Clear Overhead 13' - 0"
Max Rise 85' - 0"
Min Pit Depth 5' - 0"
  Front
Door Type Single Speed (RH/LH)
Standard Car Height 7'- 10"
Clear Inside Width 5' - 8"
Clear Inside Depth 4' - 3"
Door Width 3' - 0"
Standard Door Height 7' - 0"
Hoistway Width 7' - 4"
Hoistway Depth 5' - 9"
Speed 150
Clear Overhead 13' - 0"
Max Rise 85' - 0"
Min Pit Depth 5' - 0"
  Front Front/Rear
Door Type Single Speed (RH/LH) Single Speed (RH/LH)
Standard Car Height 7'- 10" 7'- 10"
Clear Inside Width 6' - 8" 6' - 8"
Clear Inside Depth 4' - 3" 4' - 3 1/2"
Door Width 3' - 6" 3' - 6"
Standard Door Height 7' - 0" 7' - 0"
Hoistway Width 8' - 4" 8' - 4"
Hoistway Depth 5' - 9" 6' - 8 3/4"
Speed 150
Clear Overhead 13' - 4"
Max Rise 85' - 0"
Min Pit Depth 5' - 0"
  Front Front/Rear
Door Type Single Speed (RH/LH) Single Speed (RH/LH)
Standard Car Height 7'- 10" 7'- 10"
Clear Inside Width 6' - 8" 6' - 8"
Clear Inside Depth 4' - 9" 4' - 9 1/2"
Door Width 3' - 6" 3' - 6"
Standard Door Height 7' - 0" 7' - 0"
Hoistway Width 8' - 4" 8' - 4"
Hoistway Depth 6' - 3" 7' - 2 3/4"
Speed 150
Clear Overhead 13' - 4"
Max Rise 85' - 0"
Min Pit Depth 5' - 0"
  Front Front/Rear
Door Type Single Speed (RH/LH) Single Speed (RH/LH)
Standard Car Height 7'- 10" 7'- 10"
Clear Inside Width 6' - 8" 6' - 8"
Clear Inside Depth 5' - 5" 5' - 5 1/2"
Door Width 3' - 6" 3' - 6"
Standard Door Height 7' - 0" 7' - 0"
Hoistway Width 8' - 4" 8' - 4"
Hoistway Depth 6' - 11" 7' - 10 3/4"
1. Hoistway dimensions based on 1" out of plumb and no occupied space below hoistway. If this cannot be met, consideration must be given for additional required space.
2. Pocket required for pit ladder with standard hoistway sizes.
3. Seismic Zones 2 and greater add 4" to hoistway width.
4. Seismic zones 2 or greater with only front openings and 2100 - 2500 capacity add 1" to hoistway depth.
5. Overhead requirements increase by 2” with groups of two or more cars and/or seismic conditions. For areas enforcing pre-2008 ASME A17.1 Safety Code for Elevators, contact your local representative for overhead requirements.
6. Controller closet temperature range 32°F minimum. 10-95% non-condensing relative humidity. Additional controller closet space may be required with security cabinet or additional electrical boles or features.
7. May also use two separate closets.