Building supported standard series

  • Steel, concrete or other equivalent building construction methods capable of carrying the loads of an elevator system.
  • Buildings with total floor travel up to 300’-0”.
  • Elevator capacity up to 4000 lbs.
  • Elevator speeds up to 350 fpm.
  • Standard cab finishes and flooring.

Available capacities (by weight)

Speed 200 350
Clear Overhead 14' - 9" 15' - 5"
Max Rise 300' - 0" 300' - 0"
Min Pit Depth 5' - 0" 5' - 5"
  Front Front/Rear
Door Type Single Speed (RH/LH) Single Speed (RH/LH)
Standard Car Height 7'- 10" 7'- 10"
Clear Inside Width 6' - 8' 6' - 8'
Clear Inside Depth 4' - 3" 4' - 3 1/2"
Door Width 3' - 6' 3' - 6'
Standard Door Height 7' - 0" 7' - 0"
Hoistway Width 8' - 4" 9' - 2"
Hoistway Depth 6' - 8" 6' - 8 3/4"
Speed 200 350
Clear Overhead 14' - 9" 15' - 5'
Max Rise 300' - 0" 300' - 0"
Min Pit Depth 5' - 0" 5' - 5"
  Front Front/Rear
Door Type Single Speed (RH/LH) Single Speed (RH/LH)
Standard Car Height 7'- 10" 7'- 10"
Clear Inside Width 6' - 8" 6' - 8"
Clear Inside Depth 4' - 9" 4' - 9 1/2"
Door Width 3' - 6" 3' - 6"
Standard Door Height 7' - 0" 7' - 0"
Hoistway Width 8' - 4" 9' - 2"
Hoistway Depth 7' - 2' 7' - 2 3/4"
Speed 200 350
Clear Overhead 14' - 9" 15' - 5"
Max Rise 300' - 0" 300' - 0"
Min Pit Depth 5' - 0" 5' - 5"
  Front Front/Rear
Door Type Single Speed (RH/LH) Single Speed (RH/LH)
Standard Car Height 7'- 10" 7'- 10"
Clear Inside Width 6' - 8" 6' - 8"
Clear Inside Depth 5' - 5" 5' - 5 1/2"
Door Width 3' - 6" 3' - 6"
Standard Door Height 7' - 0" 7' - 0"
Hoistway Width 8' - 4" 9' - 2"
Hoistway Depth 7' - 10" 7' - 10 3/4"
Speed 350
Clear Overhead 15' - 5"
Max Rise 300' - 0"
Min Pit Depth 5' - 5"
  Front
Door Type Single Speed (RH/LH)
Standard Car Height 7' - 10"
Clear Inside Width 7' - 8"
Clear Inside Depth 5' - 5"
Door Width 3' - 6"/4' - 0"
Standard Door Height 7' - 0"
Hoistway Width 9' - 4"
Hoistway Depth 7' - 10"
1. Hoistway dimensions based on 1" out of plumb and no occupied space below hoistway. If this cannot be met, consideration must be given for additional required space.
2. Seismic Zones 2 and greater, add 4" to hoistway width.
3. Controller closet temperature range from 32 degrees F. Min, 104 degrees F. Max. 10% - 95% Non-Condensing Relative Humidity. Add'l controller closet space may be required with security cabinet or add'l electrical boxes or features.
4. Pit ladder by others. 5" ladder req's 1'-11 1/2" x 2 1/2" notch. 7" ladder req's 1'-11 1/2" x 5" notch. Notch location varies per project.